以质量求发展,以服务铸品牌

Journal of Nursing ›› 2020, Vol. 27 ›› Issue (15): 25-28.doi: 10.16460/j.issn1008-9969.2020.15.025

Previous Articles     Next Articles

  

  • Received:2019-12-30 Online:2020-08-10 Published:2020-09-11

CLC Number: 

  • R473
[1] Gordon C.Blood Glucose Monitoring in Diabetes: Rationale and Procedure[J]. Br J Nurs, 2019, 28(7):434-439.DOI:10.12968/bjon.2019.28.7.434.
[2] Plummer MP, Bellomo R, Cousins CE, et al.Dysglycaemia in the Critically Ill and the Interaction of Chronic and Acute Glycaemia with Mortality[J].Intensive Care Med, 2014, 40(7):973-980.DOI:10.1007/s00134-014-3287-7.
[3] Klonoff DC, Umpierrez GE, Rice MJ.A Milestone in Point of Care Capillary Blood Glucose Monitoring of Critically Ill Hospitalized Patients[J]. J Diabetes Sci Technol, 2018, 12(6):1095-1100.DOI:10.1177/1932296818801607.
[4] Li X, Ma Y, Chen T, et al.Bedside Blood Glucose Monitoring in Critically Ill Patients: Comparison Between Arterial and Capillary Glucose[J]. Am. J. Med. Sci, 2017, 354(5): 458-461.
[5] Inoue S, Egi M, Kotani J, et al.Accuracy of Blood-glucose Measurements Using Glucose Meters and Arterial Blood Gas Analyzers in Critically Ill Adult Patients: Systematic Review[J]. Crit Care, 2013, 17(2): R48.DOI:10.1186/cc12567.
[6] Bala R, Ramaswami S, Ravikumar KG, et al.Comparison of Bedside and Laboratory Blood Glucose Estimations in Critically Ill Children with Shock[J]. Pediatr Crit Care Med, 2011, 12(6):297-301.
[7] 冯涛,李继东,杨晓军. 重症患者床旁指端血糖监测的准确性、一致性评价及影响因素分析[J]. 实用医学杂志, 2013, 29(12):1969-1971.
[8] 尹小生,王存,何显达,等. 休克患者末梢血糖监测的影响因素分析[J]. 护理实践与研究, 2016, 13(20):1-3.
[9] 陈源,唐云. 床旁血糖仪与生化比对方法的探索[J]. 国际检验医学杂志, 2015, 36(10):1456-1458.
[10] Hattemer A, Wardat S.Evaluation of Hematocrit Influence on Self-monitoring of Blood Glucose Based on ISO 15197:2013:Comparison of a Novel System with Five Systems with Different Hematocrit Ranges[J]. J Diabetes Sci Technol, 2018,12(2):333-340.DOI:10.1177/1932296818757550.
[11] Teodorczyk M, Cardosi M, Setford S.Hematocrit Compensation in Electrochemical Blood Glucose Monitoring Systems[J]. J Diabetes Sci Technol, 2012, 6(3):648-655.DOI:10.1177/193229681200600320.
[12] Pereira AJ, Corrêa TD, de Almeida FP, et al. Inaccuracy of Venous Point-of-care Glucose Measurements in Critically Ill Patients: A Cross-sectional Study[J]. PLoS One, 2015, 10(6):e0129568.DOI:10.1371/journal.pone.0129568.
[13] 冯涛,曹相原. 重症患者床旁血糖监测的准确性评价及影响因素分析[J]. 中华危重病急救医学, 2012, 24(8):482-486.
[14] 庞双艳. 重症患者静脉血、动脉血与末梢血血糖检测值的比较研究[D].石河子:石河子大学, 2015.
[15] 潘露,吴洪超,尹璨,等. 静脉输液对同侧肢体毛细血管血糖测量值的影响[J]. 护理学杂志, 2016, 31(11):49-51.
[16] 赵秀侠,沈玉枝,吴虹,等. 静脉输注硝酸酯类药物对输液侧指尖血糖的影响[J]. 护理学杂志, 2014, 29(21):41-42.
[17] 李俊琦,李冬,赵莹. 影响血糖检测准确性的因素分析及对策[J]. 吉林医学, 2011, 32(14):2884-2885.
[18] 刘涛,周中华. 输注维生素C对测定血糖方法的影响分析[J]. 临床医学, 2013, 33(10):97-98.
[19] Kahn SA, Lentz CW.Fictitious Hyperglycemia: Point-of-Care Glucose Measurement Is Inaccurate During High-dose Vitamin C Infusion for Burn Shock Resuscitation[J].J Burn Care Res, 2014, 36(2):67-71.
[20] Kim SK, Hahm JR, Kim HS, et al.Spurious Elevation of Glucose Concentration During Administration of High Dose of Ascorbic Acid in a Patient with Type 2 Diabetes on Hemodialysis[J]. Yonsei Med J, 2013, 54(5):1289-1292.DOI:10.3349/ymj.2013.54.5.1289.
[21] Howell AP, Parrett JL, Malcom DR.Impact of High-dose Intravenous Vitamin C for Treatment of Sepsis on Point-of-care Blood Glucose Readings[J]. J Diabetes Sci Technol, 2019:1932296819889638.DOI:10.1177/1932296819889638.
[22] 孙德华,毛欣茹,郑磊,等. 评价血细胞比容、维生素C和半乳糖等干扰因素对3种便携式血糖仪的影响[J]. 国际检验医学杂志, 2018, 39(6):651-654.
[23] Schmid C, Baumstark A, Pleus S, et al.Impact of Partial Pressure of Oxygen in Blood Samples on the Performance of Systems for Self-monitoring of Blood Glucose[J]. Diabetes Technol Ther, 2014, 16(3):156-165.DOI:10.1089/dia.2013.0184.
[24] Mahmoodpoor A, Hamishekar H, Shadvar K, et al.Validity of Bedside Blood Glucose Measurement in Critically Ill Patients with Intensive Insulin Therapy[J]. Indian J. Crit. Care Med, 2016, 20(11): 653-657.
[25] Ogawa T, Murakawa M, Matsuda A, et al.Endogenous Factors Modified by Hemodialysis May Interfere with the Accuracy of Blood Glucose-measuring Device[J]. Hemodialysis International, 2012, 16(2):266-273.
[26] King DA, Ericson RP, Todd NW.Overestimation By a Hand-held Glucometer of Blood Glucose Level Due To Icodextrin[J]. Isr Med Assoc J, 2010, 12(5):314-315.
[27] Saini S, Kaur S, Das K, et al.Using The First Drop of Blood for Monitoring Blood Glucose Values in Critically Ill Patients: An Observational Study[J]. Indian J Crit Care Med,2016,20(11):658-661.DOI:10.4103/0972-5229.194006.
[28] 曾立霞,廖浩,杨明. 两种不同仪器检测水肿重症患者血糖值比较分析[J]. 浙江临床医学, 2015(9):1615-1615.
[29] 罗桂芝,李星,鲁玫,等. ICU患者耳垂血糖与动脉血糖的一致性[J]. 广东医学, 2018, 39(19):2944-2946+2950.
[30] Chan HY, Lau TS, Ho SY, et al.The Accuracy and Acceptability of Performing Capillary Blood Glucose Measurements at the Earlobe[J]. J Adv Nurs, 2016, 72(8):1766-1773.DOI:10.1111/jan.12944.
[31] Noble M, Rippeth J, Edington D, et al.Clinical Evaluation of a Novel On-strip Calibration Method for Blood Glucose Measurement[J]. J Diabetes Sci Technol, 2014, 8(4):766-775.
[32] Baumstark A, Liebing C, Jendrike N, et al.Evaluation of Hematocrit Influence on Measurements with a Novel Self-Monitoring of Blood Glucose System Based on ISO 15197:2013[J]. J Diabetes Sci Technol, 2018, 12(5):1078-1079.DOI:10.1177/1932296818774813.
[33] Setford S, Phillips S, Grady M.Evidence From a Long-Term, Systematic Post-market Surveillance Program: Clinical Performance of a Hematocrit-insensitive Blood Glucose Test Strip[J]. J Diabetes Sci Technol, 2019: 1932296819826968.DOI:10.1177/1932296819826968.
[34] Karon BS, Blanshan CT, Deobald GR, et al.Retrospective Evaluation of the Accuracy of Roche Accuchek Inform and Nova Statstrip Glucose Meters When Used On Critically Ill Patients[J]. Diabetes Technol Ther, 2014, 16(12):828-832.DOI:10.1089/dia.2014.0074.
[35] Möller F, Liska J, Öwall A, et al.Evaluation of a Continuous Blood Glucose Monitoring System Using a Central Venous Catheter with an Integrated Microdialysis Function[J]. Critical Care, 2013, 15(1):26-31.
[36] Möller F, Liska J, Francocereceda A.Evaluation of a Continuous Blood Glucose Monitoring System Using Central Venous Microdialysis[J]. J Diabetes Sci Technol, 2012, 6(6):1365-1371.
[37] Yu J, Ding Y, Xu Q, et al.An Innovative Idea and Design Scheme of Continuous Arterial Blood Glucose Monitoring Equipment[J]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue, 2019,31(7):906-909.DOI:10.3760/cma.j.issn.2095-4352.2019.07.022.
[1] CHEN En-lin, MO Feng-ling, ZHUANG Ze-ming, ZHANG Ming-zhe, ZHOU Jia-kun, HUANG Li-fang, JI Long-fei, ZHANG Li-fang. Assessment tools for unilateral spatial neglect after stroke: a scoping review [J]. Journal of Nursing, 2025, 32(3): 43-49.
[2] WEI Li, ZHAO Xing-ying, LIU Jia, HE Yu-xuan, CHEN Xiao-mei, YANG Xue, XIAN Ji-shu, YANG Yan-ni. Care burden of family caregivers of severe inpatients in neurosurgery department and its influencing factors [J]. Journal of Nursing, 2025, 32(2): 1-6.
[3] YANG Bei, YE Hong-fang, ZHANG Ning, XIANG Lu-wei, LU Shi-yu. Current status of physical activity and its influencing factors in elderly patients with type 2 diabetes [J]. Journal of Nursing, 2025, 32(2): 7-12.
[4] CAO Min, ZHANG Pei-li, HOU Xiao-ya, GAO Chao-yue, GUO Lin-fang, LI Ying. Nutritional care experience of caregivers of colorectal cancer patients undergoing chemotherapy based on ABC-X model: a qualitative study [J]. Journal of Nursing, 2025, 32(2): 13-18.
[5] . [J]. Journal of Nursing, 2025, 32(2): 19-24.
[6] CHEN Yun, LU Yu-xuan, QI Yan-huan, MAO Jia-hui, ZHONG Yin-qin. Current status and trends of acupuncture and moxibustion in nursing of diabetic peripheral neuropathy: a bibliometric analysis [J]. Journal of Nursing, 2025, 32(2): 25-30.
[7] . [J]. Journal of Nursing, 2025, 32(2): 31-36.
[8] XIA Bi-yun, Chen Yu, WU Yan-yan, Hu Yan. Evidence-based practice to reduce incidence of radial artery occlusion in elderly patients after transradial coronary intervention [J]. Journal of Nursing, 2025, 32(2): 37-43.
[9] LIU Shuo-yi, XIONG Li-juan, LI Ling, WANG Yu-mei, HE Jia, LI Xin, YUAN Shi-lei, GUO Xue-qin, WANG Yang-jing, ZHANG Hui-juan. Quality evaluation and content analysis of clinical practice guidelines for prevention and management of frailty in elderly hospitalized patients [J]. Journal of Nursing, 2025, 32(2): 50-55.
[10] . [J]. Journal of Nursing, 2025, 32(2): 56-62.
[11] NIU Qing-mei, YU Ying, ZHANG Qian, JIA Ya-tian, TIAN Yu. Construction of follow-up management evaluation index system for patients with lower extremity atherosclerotic occlusive disease based on “three-dimensional quality structure” model [J]. Journal of Nursing, 2025, 32(2): 70-73.
[12] YAN Ya-ling, LE Mei-ni, YAO Tao-qin, WANG Xue-lian, JIANG Jian-ling, XIN Yi. Construction of perioperative frailty management program for elderly patients with gastrointestinal tumors [J]. Journal of Nursing, 2025, 32(2): 74-78.
[13] LIU Qi, LIU Jia-li, LIU Yu, YANG Li-min, FAN Yu-ying, LV Xing, JIN Hui-ying. Physical-psychological symptom burden trajectories and influencing factors in nasopharyngeal carcinoma patients during induction chemotherapy plus concurrent chemoradiotherapy [J]. Journal of Nursing, 2025, 32(1): 1-6.
[14] . [J]. Journal of Nursing, 2025, 32(1): 34-38.
[15] . [J]. Journal of Nursing, 2025, 32(1): 39-43.
Viewed
Full text


Abstract

Cited

  Shared   
No Suggested Reading articles found!