以质量求发展,以服务铸品牌

Journal of Nursing ›› 2020, Vol. 27 ›› Issue (15): 66-68.doi: 10.16460/j.issn1008-9969.2020.15.066

Previous Articles     Next Articles

Nursing Cooperation in Ozaki Technique for Aortic Valve Reconstruction: A 32-case Study

XU Bin, HAN Jie, DONG Yao, ZHANG Hong-ying   

  1. Dept. of Cardiac Operating Room , Beijing Anzhen Hospital Affiliated to Capital Medical University,Beijing Institute of Heart, Lung and Blood Vessel Diseases, Beijing 100029, China
  • Received:2019-12-16 Online:2020-08-10 Published:2020-09-11

Abstract: Objective To summarize the nursing experience in OZAKI technique for aortic valve reconstruction. Methods The data of 32 patients with aortic valve disease who underwent Ozaki procedure in our hospital from November 2015 to December 2019were collected. Instrument nurses should be familiar with surgical plan and procedures before surgery, prepare valve reconstruction equipment, and cooperate with surgeons in surgical procedures such as the preparation and suture of autologous pericardial cups. Circulating nursesshould prepare appropriate concentration of glutaraldehyde for immobilization of pericardial tissue and accurately record the duration of immersion and rinsing. Results Allthe surgeries of the 32 patients were completed successfully, achieving satisfactory results without perioperative death or nursing complications. Echocardiography was performed one week after the operation, showing satisfactory results of hemodynamic correction of aortic valve. Conclusion Nurses in operating room should be familiar with the process and technical characteristics of OZAKI technique for pericardial aortic valve reconstructionin order to assist surgeons to complete the operation successfully.Some key steps in the preparation of autopericardial leaflets as well as preparation and management of glutaraldehyde solution should be noticed during nursing cooperation.

Key words: autologous pericardium aortic valve reconstruction, aortic stenosis, aortic insufficiency, nursing cooperation

CLC Number: 

  • R472.3
[1] Komiya T.Aortic Valve Repair Update[J]. Gen Thorac Cardiovasc Surg,2015,63(6):309-19. DOI:10.1007/s11748-015-0523-1.
[2] 何文斌,廖尧,尹熙,等.心脏瓣膜置换术后患者Ⅰ期心脏康复的最佳证据总结[J].护理学报, 2019,26(18):32-36. DOI: 10.16460/j.issn1008-9969.2019.18.032.
[3] Ozaki S, Kawase I, Yamashita H, et al.A Total of 404 Cases of Aortic Valve Reconstruction with Glutaraldehyde-treated Autologous Pericardium[J]. J Thorac Cardiovasc Surg, 2014, 147(1):301-306. DOI:10.1016/j.jtcvs.2012.11.012.
[4] 孙君辉,谷静媛,郑帅,等. 5例新型自体心包主动脉瓣重建手术患者的护理[J]. 护理学报, 2016, 23(16):58-59. DOI: 10.16460/j.issn1008-9969.2016.16.058.
[5] Yamashita H, Ozaki S, Kawase I, et al.Tensile Strength of Human Pericardium Treated with Glutaraldehyde[J]. Ann Thorac Cardiovasc Surg, 2012, 18(5):434-437. DOI:10.5761/atcs.oa.11.01804.
[6] Ozaki S, Kawase I, Yamashita H, et al.Aortic Valve Reconstruction Using Autologous Pericardium for Patients Aged Less Than 60 Years[J]. J Thorac Cardiovasc Surg,2014, 148(3):934-938. DOI:10.1016/j.jtcvs.2014.05.041.
[7] 宋海娟,谢庆,韩盖宇,等. 33例Barlow综合征患者全胸腔镜Loop技术二尖瓣成形术护理配合[J]. 护理学报, 2019, 26(4):66-69. DOI:10.16460/j.issn1008-9969.2019.04.066.
Viewed